Ethernet Cable
Product Construction Parameters
Product Performance Parameters
| Product Part No. | Product Performance | ||||||||
| Electrical Properties | Mechanical Properties | Environmental Properties | |||||||
| Characteristic Impedance | Operating Frequency(MHz) | Attenuation(≤dB/m) | Data Transmission Rate | Voltage Withstand (Conductor-Conductor) |
Voltage Withstand (Conductor-Shield) |
Bending Radius | Mold Resistance | Flame Retardant | |
| ETHT-100E-4*2*24U-2 | 100±5 | 10 | 0.074 | 69 | 2.0kV | 1.5kV | 10D | Class II strains, *Scopulariopsis brevicaulis*, Grade 1 or better. | Compliant with VW-1 |
| 100 | 0.239 | ||||||||
| 200 | 0.345 | ||||||||
| 250 | 0.389 | ||||||||
| 500 | 0.566 | ||||||||
| ETHT-100E-4*2*26V-2 | 100±5 | 10 | 0.074 | 69 | 2.0kV | 1.5kV | 10D | Class II strains, *Scopulariopsis brevicaulis*, Grade 1 or better. | Compliant with VW-1 |
| 100 | 0.239 | ||||||||
| 200 | 0.345 | ||||||||
| 250 | 0.389 | ||||||||
| 500 | 0.566 | ||||||||
| ETHT-100E-4*2*28U-2 | 100±5 | 10 | 0.074 | 69 | 1.5kV | 1.5kV | 10D | Class II strains, *Scopulariopsis brevicaulis*, Grade 1 or better. | Compliant with VW-1 |
| 100 | 0.239 | ||||||||
| 200 | 0.345 | ||||||||
| 250 | 0.389 | ||||||||
| 500 | 0.566 | ||||||||